Skip to content

Duct.Create(Document, ElementId, ElementId, Connector, XYZ)

Public Class

Creates a new duct that connects to the connector.

Namespace: Autodesk.Revit.DB.Mechanical

Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Syntax

public static Duct Create(
Document document,
ElementId ductTypeId,
ElementId levelId,
Connector startConnector,
XYZ endPoint
)

Parameters

document Document

The document.

ductTypeId ElementId

The ElementId of the new duct type.

levelId ElementId

The level id for the new duct.

startConnector Connector

The first connector where the new duct starts.

endPoint XYZ

The second point of the new duct.

Return Value

Duct
The created duct.

Exceptions

Exception

Condition


ArgumentException

The duct type ductTypeId is not valid duct type. -or- The ElementId levelId is not a Level. -or- The connector’s domain is not Domain.​DomainHvac. -or- The points of startConnector and endPoint are too close: for MEPCurve, the minimum length is 1/10 inch.


ArgumentNullException

A non-optional argument was null


InvalidOperationException

Thrown when the new duct fails to connect with the connector.


Remarks

The new duct will have the same diameter and system type as the specified connector. The creation will also connect the new duct to the component who owns the specified connector. If necessary, additional fitting(s) are included to make a valid connection. If the new duct can not be connected to the next component (e.g., mismatched direction, no valid fitting, and etc), the new duct will still be created at the specified connector position, and an InvalidOperationException is thrown.