AnalyticalPowerDistributableNodeData.SetConnectedPhasesOnDownstream

Public Class

Set the electrical connected phases of the downstream node.

Namespace: Autodesk.Revit.DB.Electrical

Assembly: RevitAPI (in RevitAPI.dll) Version: 25.0.0.0 (25.0.0.0)

Syntax

public void SetConnectedPhasesOnDownstream(
ElementId id,
ElectricalConnectedPhases connectedPhases
)

Parameters

id ElementId

The downstream node id.

connectedPhases ElectricalConnectedPhases

The electrical connected phases to set to the downstream node.

Exceptions

Exception

Condition


ArgumentException

The id isn’t a downstream node id of the power distributable node. -or- The electrical connected phases can’t be used to connect the downstream node to the power distributable node.


ArgumentNullException

A non-optional argument was null


ArgumentOutOfRangeException

A value passed for an enumeration argument is not a member of that enumeration


Remarks

If node B supplies from node A, node B is the downstream node of node A, and node A is the upstream node of node B. Usually one node may have many downstream nodes, but TransferSwitch can only have one downstream node.